630A 35kV 4 Position Oil Loadbreak Switch – for Pad-Mounted Transformer

630A 35kV 4 Position Oil Loadbreak Switch – for Pad-Mounted Transformer

pad mounted transformer load break switch oil loadbreak switch for padmount transformer 35kV transformer load switch
Send Inquiry
Description

Wenzhou Shuowei Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 630a 35kv 4 position oil loadbreak switch – for pad-mounted transformer in China, also supports customized service. Welcome to wholesale bulk advanced 630a 35kv 4 position oil loadbreak switch – for pad-mounted transformer in stock here from our factory. If you have any enquiry about quotation, please feel free to email us.

 

630A 35kV 4 Position Oil Loadbreak Switch – for Pad-Mounted Transformer

 

20260520110925257351

The 630A 35kV 4 Position Oil Loadbreak Switch is specifically designed for integration into pad-mounted transformers and compact secondary substations. It serves as the primary high-voltage switching, protection, and grounding device – combining load break, isolation, and earth grounding in a single oil-immersed unit.

Rated at 630A continuous current and 35kV (40.5kV insulation level), this 4-position switch provides: CLOSE (normal operation), OPEN (load break), ISOLATE (visible isolation gap), and EARTH (maintenance grounding). The oil-immersed design ensures excellent arc extinction and reliable operation in outdoor pad-mounted transformer enclosures.

 

2
Main technical parameters-fYN33 lbor Switch
Item   Unit FYN33-12/630 FYN33-40.5/630
Rated voltage   kV 12 40.5
1min power frequency withstand voltage Earth interphase kV 42 95
Isolation clearance kV 48 118
lightning surge withstand voltage Earth interphase kV 75 200
Isolation clearance kV 85 215
Rated current (A)   A 630 630
Rated thermostable current/2S, 4S   KA 20/2S 25/4S
Rated dynamic current   KA 50 63
Mechanical life   time >2000 >2000

 

3
Overall dimension-fYN33 lbor Switch

 

2

Q: Why is a 4-position switch used in pad-mounted transformers?
A: It provides load breaking (Close/Open), visible isolation (Isolate), and maintenance grounding (Earth) – all required for safe transformer servicing.

 

Q: What is the difference between Isolate and Earth positions?
A: Isolate provides a visible air gap (circuit open but not grounded). Earth closes the grounding switch. Both are required for safety procedures.

 

Q: Does this switch fit all pad-mounted transformer enclosures?
A: Flange patterns and shaft lengths vary by manufacturer. Send us your drawing – we can match.

 

Q: Is mechanical interlock included?
A: Yes. Prevents opening transformer compartment unless switch is in Earth or Isolate position.

 

Q: Can the switch be operated from outside the transformer?
A: Yes. The handle extends through the front panel door. Padlocking available for each position.

 

Q: What standards apply to pad-mounted transformer switches?
A: IEEE C57.12.34 is the primary standard for pad-mounted transformer enclosures and integrated switching.

Hot Tags: 630A 35kV 4 Position Oil Loadbreak Switch – for Pad-Mounted Transformer, China 630A 35kV 4 Position Oil Loadbreak Switch – for Pad-Mounted Transformer manufacturers, suppliers, factory, 12kV 630A Four Position Loadbreak Switch, Two Position Loadbreak Switch, 35kV 630A Two Position Loadbreak Switch, Four Position Oil Immersed Load Break Switch, 25kV 630A Type Two Position Oil Immersed Load Switch, Medium Voltage Oil Immersed Four Position 15kV Load Break Switches LBS