Low Voltage Bushing

Your Professional Low Voltage Bushing Supplier

 

Wenzhou Shuowei Electric Co., Ltd. (SUVELL)is a high-tech enterprise specializing in the research, development, production and sales of transformer accessories, switch cabinet accessories, cable accessories, power fittings and transmission line accessories.

Our product portfolio includes pad-mounted transformers, pole-mounted transformers, oil-immersed load break switches, switchgear systems, and switchgear components.

 

 
  • 1.2kV 3000A Epoxy LV Bushings
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 1.2kV 2000A low voltage epoxy resin Bushing
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 1.2kV 1600A low voltage Epoxy resin Bushings
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 1.2kV 1000A Epoxy resin Bushings
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 630A Epoxy LV Bushings
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 400A low voltage Epoxy resin Bushing
    This product line is designed for secondary bushings in liquid-filled transformers. Available in copper and aluminum, copper bushings are made of C110 electrolytic copper with silver brazed...
    read more
  • 1.2kV 1200A Thermoplastic LV bushings
    1) Voltage class 1.2 kV, BlL 30kV, AC withstand voltage 10kV/min
    2) Continuous current: 1500A
    3) Application temperature -40~140℃, Indoor condition without salt fog and chemical...
    read more
  • 1KV 250A Bushing
    Transformer bushing is an outlet device for the high and low voltage leads inside the transformer to the outside of the fuel tank. It has specified electrical strength and adequate mechanical...
    read more
  • 1KV/400A Bushing
    Transformer bushing is an outlet device for the high and low voltage leads inside the transformer to the outside of the fuel tank. It has specified electrical strength and adequate mechanical...
    read more
  • 1KV 800A Bushing
    Transformer bushing is an outlet device for the high and low voltage leads inside the transformer to the outside of the fuel tank. It has specified electrical strength and adequate mechanical...
    read more
  • 200A-3000A Bushing
    Transformer bushing is an outlet device for the high and low voltage leads inside the transformer to the outside of the fuel tank. It has specified electrical strength and adequate mechanical...
    read more
First 12 Last
 
Why Choose us
 
 

Quality Assurance

The company is equipped with comprehensive production facilities and a robust testing system to ensure that all products meet international standards and satisfy customer requirements.

 
 
 

Professional Solution

With extensive experience and personalized one-to-one service, we are capable of assisting you in selecting suitable products and providing professional answers to technical inquiries.

 
 
 

Reasonable Price

Supported by a dedicated procurement and cost-control team, we strive to minimize production costs and optimize profit margins in order to offer you competitively priced solutions.

 

 

Parameter

 

 

Parameter

Specification

Voltage Class

1.2 kV

Basic Impulse Level (BIL)

30 kV

AC Withstand Voltage

10 kV/min

Continuous Current

1500 A

Operating Temperature

-40°C to +140°C

Environmental Condition

Indoor (no salt fog/chemical corrosion)

Conductor Material

Copper (C11000)

Insulation Body Color

Black

Recommended Tank Hole Diameter

45.0 ±0.5 mm

Sealing Gasket

As per left-view diagram

Customization

Dimensions adjustable per customer requirements

 

Customization Process

Communication Requirements

Terminal connectors can be customized according to customer specifications, thereby facilitating seamless integration into existing equipment and streamlining the installation process.

Production Execution

Following the confirmed design, we implement meticulous production processes with strict quality control at every stage, ensuring consistency and precision before proceeding to mass production.

5/8' Intergral Clamp Bushing
1.2KV 3000A

Quality Inspection and Packaging

Upon completion of the product, a comprehensive three-stage inspection process is conducted to ensure quality standards are met. Subsequently, the products are packaged in accordance with your specified requirements.

Delivery Assurance

We ensure timely delivery of the products within the agreed timeframe as per the contract terms.

 

Features of Low Voltage Bushing
 
 
 

Electrical Insulation

Electrical insulation is the primary and most critical feature of low voltage bushings. These components create a robust barrier that prevents electrical current from escaping or leaking between different voltage levels. The insulation material is carefully selected to withstand high electrical stress, ensuring that electricity flows only through the intended path.

 
 

Mechanical Support

Low voltage bushings provide crucial mechanical support for electrical conductors. They act like sturdy mounting points that hold electrical connections firmly in place, preventing movement, vibration, or physical stress that could damage the electrical system.

 
 

Voltage Grading

Voltage grading is a sophisticated feature that helps distribute electrical stress evenly across the low voltage bushing. This prevents concentration of electrical pressure at any single point, which could lead to breakdown or failure. The voltage grading system uses multiple layers of insulation and conductive materials that create a gradual transition of electrical potential.

 
 

Environmental Protection

Low voltage bushings are engineered to provide exceptional environmental protection. They act as a shield that protects internal electrical components from external factors like moisture, dust, pollution, and extreme temperatures. The outer shell of the bushing is designed to be weather-resistant and capable of maintaining its structural integrity in challenging conditions.

 

 

 

Delivery Information

Shipping Methods: We offer a variety of shipping options, including sea freight, air freight, railway transportation, and international express delivery, to meet the diverse needs of our customers.

 

Estimated Delivery Time: We will provide you with the estimated delivery time for your order, which will be clearly stated in the formal order to ensure your rights are protected, allowing you to arrange for the receipt of your goods in a timely manner.

 

Order Tracking: We provide order tracking services, allowing you to stay informed about the current status and expected arrival time of your order. Detailed inspection information and shipping manifests, including photos and videos, are provided to ensure the security of your transactions.

1.2KV 1600A

 

 

FAQ

 

 

Q: What is a low voltage bushing?

A: Low voltage bushings are designed to allow power or signals to pass through a conductive barrier, while maintaining electrical isolation and protecting the system from electrical breakdown.

Q: Why do transformer bushings fail?

A: Transformer bushings can fail due to a combination of factors including insulation degradation, mechanical stress, and environmental conditions. Specifically, moisture ingress, thermal stress, electrical overloading, and contaminants in the oil can all contribute to bushing failure. Aging materials and improper installation or processing also play a role.

Q: What is the power factor limit for bushings?

A: The dissipation factor – or power factor – of a bushing is the ratio of the resistive current component to the total leakage current under applied voltage. Generally speaking, a power factor of less than 1% for oil-impregnated paper (OIP) bushings is considered good, while 1% to 2% is regarded as questionable.

Q: How do you test a transformer bushing?

A: The main testing methods for transformer bushings are capacitance and tan delta (C and tan δ), power factor (PF), and partial discharge (PD). These methods measure the dielectric properties and the quality of the insulation system of the bushings, and can detect defects, deterioration, and contamination.