Fuse Potential Transformer Series

Your Professional Fuse Potential Transformer Series Supplier

 

Wenzhou Shuowei Electric Co., Ltd. (SUVELL)is a high-tech enterprise specializing in the research, development, production and sales of transformer accessories, switch cabinet accessories, cable accessories, power fittings and transmission line accessories.

Our product portfolio includes pad-mounted transformers, pole-mounted transformers, oil-immersed load break switches, switchgear systems, and switchgear components.

 

 
 
Why Choose us
 
 

Quality Assurance

The company is equipped with comprehensive production facilities and a robust testing system to ensure that all products meet international standards and satisfy customer requirements.

 
 
 

Professional Solution

With extensive experience and personalized one-to-one service, we are capable of assisting you in selecting suitable products and providing professional answers to technical inquiries.

 
 
 

Reasonable Price

Supported by a dedicated procurement and cost-control team, we strive to minimize production costs and optimize profit margins in order to offer you competitively priced solutions.

 

 

Parameter

 

 

2024112514013090e59.jpg (800×307)

 

10kv Combined Three Phase Potential Transformer with Fuse

 

Benefits of Fuse Potential Transformer Series

Measures very high voltages on transmission lines safely.

 

Enables an ordinary voltmeter to measure very high voltages.

 

Provides protection by electrically isolating the voltmeter and high-voltage line.

 

Precautions for the Use of Fuse Potential Transformer Series
 

The fuse potential transformer shall be tested and inspected in accordance with the items specified in the regulations before being put into operation, like measuring polarities, connecting groups, shaking insulations, checking phase sequence, etc...

 

The wiring of the fuse potential transformer should be correct. The primary winding should be connected in parallel with the circuit under test, and the secondary winding should be connected in parallel with the voltage coil of the connected measuring instrument, relay protection device, or automatic device. At the same time, pay attention to the correctness of the polarity.

 

The capacity of the load connected to the secondary side of the potential transformer should be appropriate, and the load connected to the secondary side of the potential transformer should not exceed its rated capacity. Otherwise, the error of the transformer will increase and it is difficult to achieve the accuracy of the measurement.

 

Short circuit is not allowed on the secondary side of the potential transformer. Since the internal impedance of the potential transformer is very small, if the secondary circuit is short-circuited, a large current will appear, which will damage the secondary equipment and even endanger personal safety.

 

In order to ensure the safety of people when touching measuring instruments and relays, the secondary winding of the potential transformer must be grounded. Because after grounding, when the insulation between the primary and secondary windings is damaged, it can prevent the instrument and relay from appearing high voltage and endangering personal safety.

 

No short circuit is allowed on the secondary side of the potential transformer.

 

 

Application of Fuse Potential Transformer Series

Relay and metering circuits

 

Electrical protection systems

 

Measuring high-voltage transmission lines

 

Synchronizing power generators and feeders( feeders are the power line through which electricity is transmitted in power systems)

35kv Single Potential Transformer with Fuse

 

 

Additional Information

 

 

Shipping

We offer various shipping methods, including sea freight, air freight, and express delivery, depending on the order size and destination.

Terms Of Payment

We usually accept T/T, L/C, Paypal, Credit card, etc. If you prefer other payments terms, please feel free to discuss with us.

 

 

FAQ

 

 

Q: How to determine fuse size for transformer?

A: In lieu of transformer inrush data, the rule of thumb is to select a fuse size rated at 300% of the primary full-load current and round up to the next larger standard size.

Q: How to test a potential transformer?

A: To test a potential transformer (PT), also known as a voltage transformer (VT), several tests can be performed to assess its functionality and safety. These include insulation resistance tests, winding resistance tests, polarity tests, ratio tests, and burden tests. Additionally, dielectric tests, magnetic balance tests, and excitation (saturation) tests can be conducted.

Q: How do you select fuses for transformers?

A: Primary fuses must be able to handle the high inrush current of a transformer. This can be as much as 30 x calculated current for . 01 seconds. A time delay dual-element fuse is recommended.

Q: Why do transformer fuses blown?

A: If the load exceeds allowed overload limits of the transformer, the excessive current flow can potentially cause the fuse to blow. Overloading can be caused by connecting too many electrical devices to a transformer, or by a sudden surge in demand for power.

We're professional fuse potential transformer series manufacturers and suppliers in China, specialized in providing high quality customized service. We warmly welcome you to wholesale bulk fuse potential transformer series in stock here from our factory. Contact us for quotation.

10kv Three Phase Potential Transformer With Fuse, 35kv Single Potential Transformer With Fuse, fuse potential transformer series