High Voltage Bushing

Your Professional High Voltage Bushing Supplier

 

Wenzhou Shuowei Electric Co., Ltd. (SUVELL)is a high-tech enterprise specializing in the research, development, production and sales of transformer accessories, switch cabinet accessories, cable accessories, power fittings and transmission line accessories.

Our product portfolio includes pad-mounted transformers, pole-mounted transformers, oil-immersed load break switches, switchgear systems, and switchgear components.

 

 
  • Transformer Monoblock Bushing
    Location: Indoor/0utdoor Rated voltage : 1.1 kV to 3.6 kV Rated Current: Upto 7500 Amps Type: Air /oil
    read more
  • 25kV 200A High Voltage Bushing Well
    High Voltage 15kv 200a Bushing Well Dacromet (Dacrotized) Process: ROHS-compliant surface treatment Superior Corrosion Resistance: 500–1000 hours salt spray test High-Temperature Resistance: Up...
    read more
  • 600A 15kV Deadbreak T Connector
    The 600A Dead break T-type connector plug is used to connect two or more 600A circuit breaker terminals. Circuit breaker connector plugs are typically used at separable joints or in conjunction...
    read more
  • 35kV 600A Bushing Insert
    The epoxy bushings are designed for sidewall mounting in transformers, switches and other apparatus filled with transformer oil, the bushing includes an internal ground screen. Electrical...
    read more
  • 15kV 200A Bushing Insert
    Bushing inserts are threaded into a universal well to function like an integral loadbreak bushing, enabling efficient field installation and replacement. They are key components of loadbreak...
    read more
  • 25kV 600A ANSI Deadbreak Apparatus Bushing
    25kV 600A ANSI Deadbreak Apparatus Bushing 15/25kV 600A bushing insert for pad mounted transformer, designed to provide electrical insulation and safe passage of current through the transformer's...
    read more
  • 200A Tri Clamp Bushing Well
    200 AMP bushing wells are designed to improve the reliability of pad mount transformers. The "Tri-Clamp Bushing Well" is the first bolted-design bushing well capable of being mounted directly onto...
    read more
  • epoxy resin plug in bushing
    epoxy resin plug in bushing,we have type A and C for your reference.
    read more
  • 25kv 250A Bushing
    25kV 250A Bushing provide the interface for the 200A Cable connector and mostly used on the oil-insulated (R-temp, hydrocarbon, or silicone) apparatus, including switchgear, transformers, and...
    read more
  • 35kv 315A Bushing
    35kV 315A Bushing provide the interface for the 200A Cable connector and mostly used on the oil-insulated (R-temp, hydrocarbon, or silicone) apparatus, including switchgear, transformers, and...
    read more
  • 35kV 630A Bushing
    35kV 630A Bushing provide the interface for the 200A Cable connector and mostly used on the oil-insulated (R-temp, hydrocarbon, or silicone) apparatus, including switchgear, transformers, and...
    read more
 
Why Choose us
 
 

Quality Assurance

The company is equipped with comprehensive production facilities and a robust testing system to ensure that all products meet international standards and satisfy customer requirements.

 
 
 

Professional Solution

With extensive experience and personalized one-to-one service, we are capable of assisting you in selecting suitable products and providing professional answers to technical inquiries.

 
 
 

Reasonable Price

Supported by a dedicated procurement and cost-control team, we strive to minimize production costs and optimize profit margins in order to offer you competitively priced solutions.

 

 

Parameter

 

 

Parameter

Specification

Rated Voltage (Phase-to-Phase)

35kV

Withstand Voltage (50/60Hz)

50kV/1min

BIL and Full Wave Crest

150kV

Minimum Corona Voltage Level

26kV

Continuous Current

600/900A

Short Time Withstand Current

25kA rms sym. (0.17s)
10kA rms sym. (0.17s)

 

Benefits of High Voltage Bushing

Safety

Electricity at high voltages can cause fires, explosions, or shocks if it arcs or discharges from the transformer. High voltage bushings hold the electricity inside and prevent it from leaking out.

They keep high-voltage electricity safely contained, which is especially important in areas like residential neighborhoods where transformers are close to people.

Reliability

By preventing electrical faults, bushings help transformers operate without interruptions. A reliable transformer means fewer power outages and less downtime for homes and businesses.

25KV 200A Bushing Well
600A 15kV Deadbreak T Connector

Efficiency

Bushings reduce the chance of faults, like sparks or overheating, that can stop a transformer from working. A functional high voltage bushing will reduce energy waste and keep the transformer running at optimal performance.

Longevity

High voltage bushings are designed to handle the stress of high-voltage electricity, extreme weather, and daily wear and tear. This durability helps extend the life of the transformer and reduces maintenance costs.

 

Function Of High Voltage Bushing

Insulating Electricity

All electrical power flow through conductors carries a significant risk: inadvertent discharge to ground. Also known as "ground faults," these hazardous events may cause arcing, fires, or explosions. High voltage bushing provide the insulating protection necessary to guard conductors so that power flow occurs safely.

Guiding Electrical Flow

In addition to providing insulation, high voltage bushings also guide electrical current between the transformer' s internal windings and the external power lines. They do this by allowing a conductor to pass safely through the transformer' s grounded casing without making direct contact. Inside, the high voltage bushing contains alternating layers of conductive and insulating materials. These layers use a method called capacitive grading, which helps distribute electrical stress more evenly along the length of the high voltage bushing. This prevents the buildup of hotspots that could lead to failure.

Controlling Stress

Handling high-voltage electricity places immense stress on the bushing's materials. Over time, this can lead to wear, overheating, or even failure. To counteract this, advanced bushing designs include stress-control layers or utilize materials with high thermal resistance and low electrical loss. These features distribute electrical stress evenly and minimize the risk of breakdowns.

 

 

Delivery Information

Shipping Methods: We offer a variety of shipping options, including sea freight, air freight, railway transportation, and international express delivery, to meet the diverse needs of our customers.

 

Estimated Delivery Time: We will provide you with the estimated delivery time for your order, which will be clearly stated in the formal order to ensure your rights are protected, allowing you to arrange for the receipt of your goods in a timely manner.

 

Order Tracking: We provide order tracking services, allowing you to stay informed about the current status and expected arrival time of your order. Detailed inspection information and shipping manifests, including photos and videos, are provided to ensure the security of your transactions.

04

 

 

FAQ

 

 

Q: How do high voltage bushings work?

A: These seemingly simple devices perform the critical function of carrying current at high voltage through equipment enclosures. They perform this function by providing an insulating barrier between the live conductor and the metallic (conducting) body of the electrical apparatus (which is at ground potential).

Q: Why do transformer bushings fail?

A: Transformer bushings can fail due to a combination of factors including insulation degradation, mechanical stress, and environmental conditions. Specifically, moisture ingress, thermal stress, electrical overloading, and contaminants in the oil can all contribute to bushing failure. Aging materials and improper installation or processing also play a role.

Q: How do you test a transformer bushing?

A: This involves applying a specific DC voltage while measuring the insulation resistance over time to check for moisture or deterioration. After this, carry out a capacitance and power factor test to evaluate the dielectric loss characteristics of the bushing.

Q: What is C1 and C2 in transformer bushing?

A: The capacitance of the multiple layers between the core and the test tap, or between the core and the potential tap, is represented by C1. The test tap is isolated from the grounded flange when the tap cover is removed, and the capacitance of this insulation is represented by C2.

We're professional high voltage bushing manufacturers and suppliers in China, specialized in providing high quality customized service. We warmly welcome you to wholesale bulk high voltage bushing in stock here from our factory. Contact us for quotation.

25kv 250A Bushing, high voltage bushing, 35kv 315A Bushing