40.5kV SF6 LoadBreak Switch

40.5kV SF6 LoadBreak Switch

40.5kV Indoor SF6 Switch-Disconnector FL(R)N36 Load Break Switch LBS is a double-break rotary load switch using SF6 gas for insulation and arc quenching. It's designed for 35-40.5kV power distribution systems and is permanently sealed with 0.4bar SF6 gas. The switch can be installed vertically or horizontally, typically with a steel partition separating the cable and busbar rooms in ring main units for safety compliance.
Send Inquiry
Description

Wenzhou Shuowei Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 40.5kv sf6 loadbreak switch in China, also supports customized service. Welcome to wholesale bulk advanced 40.5kv sf6 loadbreak switch in stock here from our factory. If you have any enquiry about quotation, please feel free to email us.

 

40.5kV Indoor FL(R)N36 Load Break Switch LBS-SF6 Switch-Disconnector

 

 

 

Products Description

 

 

40.5kV Indoor SF6 Switch-Disconnector FL(R)N36 Load Break Switch LBS is a double-break rotary load switch using SF6 gas for insulation and arc quenching. It's designed for 35-40.5kV power distribution systems and is permanently sealed with 0.4bar SF6 gas. The switch can be installed vertically or horizontally, typically with a steel partition separating the cable and busbar rooms in ring main units for safety compliance.


Combining FLN36-40.5kV indoor high-voltage SF6 load switch with other electrical components enables control and protection functions, serving as the control and protection for electrical equipment in various applications. It's used for managing load and overload currents, as well as no-load long lines, transformers, and capacitor banks. The load switch combined with a current-limiting fuse can replace a circuit breaker, with the load switch handling various load currents and the fuse managing larger overloads and short-circuit currents.
The product meets GB3804, GB16926, IEC 60265-1, and IEC60420 standards.

 

Products Parameters

 

No. Parameter Unit FLN36-40.5 FLRN36-40.5 Notes
1 Rated voltage kV 40.5 40.5 -
2 Rated frequency Hz 50 50 (Typo corrected)
3 Rated current A 630 1250 -
4 Rated insulation level        
  1min power-frequency withstand voltage        
  - Phase-to-phase kV 85 85  
  - Phase-to-earth kV 85 85  
  - Fracture kV 110 110  
  Lightning impulse withstand voltage (peak)        
  - Phase-to-phase kV 185 185  
  - Phase-to-earth kV 185 185  
  - Fracture kV 215 215  
5 Auxiliary circuit 1min power-frequency withstand voltage V 2000 2000 -
6 Rated thermal stability current (3s/2s)        
  - Switch kA 20 20  
  - Earthing switch kA 20 20  
7 Rated short-circuit making current kA 50 125  
8 Rated closed-loop breaking current A 630 630  
9 Rated active load breaking current A 630 630  
10 Rated cable charging breaking current A 10 10  
12 Rated transfer current A 1700 1700  
13 Expected short-circuit breaking current kA 50 50  
14 Mechanical life Times 2000 2000  
15 SF₆ gas rated pressure (20°C, gauge) MPa 0.06 0.06  
16 SF₆ gas max pressure (20°C, gauge) MPa 0.07 0.07  
17 Annual leakage rate %/Y 0.5 0.5  
18 Opening/closing synchronicity ms ≤3 ≤3  
19 Circuit resistance μΩ ≤100 ≤100  

Fuse Rated Parameters

No. Rated Voltage (kV) Fuse Rated Current (A) Fuse Link Rated Current (A) Rated Breaking Current (kA)
1 40.5 40 6.3, 10, 16, 20, 25, 31.5, 40 40
2 40.5 100 50, 63, 80, 100 40
3 40.5 125 125 50

 

 

Products Dimensions

 

 

 

1733990653444

1733990673878

 

Products Structural Features

 

 

1. The load switch using double break points and rotating movable contacts has three states: closed, open, and grounded.
2. It has excellent insulation performance. The load switch uses SF6 gas as the arc extinguishing and insulation medium, and is sealed by encapsulating the upper and lower shells with epoxy resin.
3. Excellent safety performance. If an internal arc occurs, the weak point of the rear structure of the shell will break, and then the arc exhaust valve on the cabinet will open, directing high-pressure airflow outside the cabinet.
4. Supports manual or electric operation, with convenient and reliable operation.
5. Three phase overall installation, good periodicity, few components, easy adjustment and installation, easy operation and long service life.
6. Each load switch is sealed for life and does not require maintenance.
7. The load switch and operating mechanism are placed in a detachable upper unit. It is easy to convert the load switch cabinet into a load switch+fuse combination electrical cabinet, or vice versa.
8. Suitable for compact, miniaturized, and frequently operated situations.

 

64-2-1024x1007

 

 

Products Usage Environment

 

 

 

No. Parameter Specification Notes
1 Ambient Temperature Upper limit: +40℃
Lower limit: -15℃
Operating temperature range
2 Environmental Humidity Daily average relative humidity ≤95%
Monthly average relative humidity ≤90%
Moisture conditions
3 Altitude Maximum installation altitude: 2000m Elevation limit
4 Seismic Resistance Maximum earthquake intensity: 8 degrees Seismic design standard
5 Air Quality Requirements No severe pollution including:
- Dust/smoke
- Chemical corrosives
- Flammable gases
- Gasoline/salt agents
Clean air environment
6 Special Requirements Must be specified when ordering Customization available

 

Products Packing

 

42424242424242.jpg

 

Products FAQ

 

Q: Q 1. Are you factory?

A: A.YES, Welcome to visit our company and factory.

Q: Q 2. How's the delivery time?

A: A. Usually it will take about 7-30 days for MOQ.

Q: Q 3.Can you design customer's packing?

A: A.YES.We can customized the package for you.

Q: Q 4.Do you have ability for OEM/ODM cooperation?

A: A.OEM/ODM cooperation is welcomed. And we have full experience about them.

Q 5.We wants to know month capacity.
A. lt depends on which model. Generally, month capacity can reach near 100,000pcs.

 

 

 

Hot Tags: 40.5kV SF6 LoadBreak Switch, China 40.5kV SF6 LoadBreak Switch manufacturers, suppliers, factory, FN7 12 KV Indoor H V Load Breaking Switch With Fuse, Indoor H V Vacuum Load Break Switch