35kV 600A Bushing Insert – IEEE 386 Load Break / Dead Break for ANSI Pad-Mounted Transformer

35kV 600A Bushing Insert – IEEE 386 Load Break / Dead Break for ANSI Pad-Mounted Transformer

600A bushing insert 35kV bushing insert IEEE 386 bushing insert 600A separable connector insert load break bushing insert
Send Inquiry
Description

Wenzhou Shuowei Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 35kv 600a bushing insert – ieee 386 load break / dead break for ansi pad-mounted transformer in China, also supports customized service. Welcome to wholesale bulk advanced 35kv 600a bushing insert – ieee 386 load break / dead break for ansi pad-mounted transformer in stock here from our factory. If you have any enquiry about quotation, please feel free to email us.

 

35kV 600A IEEE 386 bushing insert

 

 

51

24

The 35kV 600A Bushing Insert is a precision-engineered separable connector component designed for ANSI/IEEE standard medium voltage underground distribution systems. It serves as the interface (male contact) that inserts into the 200A or 600A bushing mounted on pad-mounted transformers, switchgear, or RMUs, enabling connection of 600A T-bodies, elbows, or feed-through connectors.

Rated for 35kV class systems (34.5kV) and 600A continuous current, this bushing insert is fully compliant with IEEE 386 (standard for separable insulated connectors). It is available in both load break and dead break versions, suitable for underground cable termination, transformer primary connection, and switchgear interface applications.

 

Products parameters

 

Parameter Specification
Rated Voltage (Phase-to-Phase) 35kV
Withstand Voltage (50/60Hz) 50kV/1min
BIL and Full Wave Crest 150kV
Minimum Corona Voltage Level 26kV
Continuous Current 600/900A
Short Time Withstand Current 25kA rms sym. (0.17s)
10kA rms sym. (0.17s)

 

Products Installation

 

 

No special tools are required. The bushing is mounted through the apparatus sidewall and clamped externally.

 

image001

 

 

Products Kit

 

 

image003

 

 

Products packing

421421426263.jpg

 

 

Products FAQ

 

Q: Is this compatible with Elastimold / Cooper / Eaton 600A systems?
A: Yes. IEEE 386 ensures full interchangeability with all major brand 600A separable connectors.

 

Q: What is the difference between load break and dead break insert?
A: Load break can be disconnected under load (with arc snuffer). Dead break requires circuit de-energized before disconnection.

 

Q: What cable sizes does this accept?
A: Typically #2 AWG to 500 kcmil . Specify your cable size when ordering.

 

Q: Is this submersible?
A: Yes. Fully submersible design for underground vaults and direct burial applications.

 

Q: Do you provide test reports?
A: Yes. AC withstand, partial discharge, contact resistance, and corona tests available.

 

 

 

 

Hot Tags: 35kV 600A Bushing Insert – IEEE 386 Load Break / Dead Break for ANSI Pad-Mounted Transformer, China 35kV 600A Bushing Insert – IEEE 386 Load Break / Dead Break for ANSI Pad-Mounted Transformer manufacturers, suppliers, factory, high voltage bushing, 35kv 315A Bushing, 25kv 250A Bushing