The low-voltage bushing in the transformer is a key component on the low-voltage side of the transformer. Its function, structure, and requirements are as follows:

Function

Electrical insulation: As an external insulation device for the low-voltage winding lead to the ground, it prevents the winding from short-circuiting with the transformer tank.

Mechanical support: Fix the low-voltage lead to avoid stress damage caused by vibration or thermal expansion and contraction, and ensure the stability of equipment operation.

Current conduction: The low-voltage current is led out to the external circuit through the conductive rod to ensure the continuity of power transmission.

Structure

The low-voltage bushing consists of a live part and an insulating part:

Live part: including conductive rods, conductive tubes, cables, or terminal blocks, responsible for current conduction.

Insulation part:

External insulation: Porcelain sleeves are used to provide insulation to the ground and protect the inner insulation layer.

Internal insulation: It can be a porcelain sleeve, a rubber sleeve, or a voltage-equalizing accessory to ensure uniform distribution of the internal electric field.

Technical requirements

Electrical strength: It must meet the insulation requirements under the rated voltage of the transformer. For example, bushings of 10 kV and below must pass the power frequency withstand voltage test.

Mechanical strength: withstand the instantaneous electric force and lead weight during a short circuit to avoid deformation or damage.

Thermal stability: operate for a long time at rated temperature rise, withstand instantaneous overheating during short circuit, and ensure that the insulation performance does not deteriorate.

Environmental adaptability:

Moisture and anti-fouling: outdoor bushings must be hydrophobic to prevent surface flashover.

Weather resistance: materials must withstand ultraviolet rays, ozone, and temperature changes to extend service life.

Application scenarios

Low-voltage bushings are widely used in the low-voltage side of oil-immersed transformers, dry-type transformers, and special transformers (such as rectifier transformers) and are commonly found in:

Power system: transformer low-voltage side outlets of substations and distribution stations.

Industrial field: distribution transformers in metallurgy, the chemical industry, and other industries.

New energy field: box transformers for wind power and photovoltaic power stations.